Digital benchtop pH meter.
Automatic pH calibration on different families of buffers, or manual (5 values).
Automatic and manual 1-point ORP calibration.
Retrieve and print out calibration data. Graphic display of electrode conditions.
Calibration deadline warning and/or measurement block.
Functions for setting alarms and displaying in analog format, "Freeze-reading" and "Stability" with titration mode (Tit) and time stability for ISE, self-diagnosis messages.
Numeric password for saved data protection and calibration management.
Data logger up to 1000 data in GLP with the possibility of sending to printer or PC.
Multilingual Setup Menu (Ita – Eng – Deu – Fra – Esp – Por).
Free Data-Link + software for PC data management.
USB output for PC connection and RS232 port for printer connection.
Independently controlled magnetic stirrer (optional).
Measuring range:
pH: -2.000…16.000 (0.01 pH)
mV: –2000…+2000 (0.1/1mV)
ORP: –2000…+2000 (0.1/1mV)
Temperature: -20…120.0 °C (0.1 °C)
Supplied as standard:
S7/BNC cable, NT 55 temperature probe, electrode holder stand, colored buffer solutions, USB cable and multi-socket power supply.
Characteristics
Accuracy pH±0.002pH
Accuracy Temperature±0.2 °C
Power supply 100 - 240V
GLPSi calibration
DHSSi compatibility
Temperature compensation0.0 ... +100.0 °C
Automatic and manual temperature compensation Yes
PCUSB type B communication
RS 232 printer connection
Measurement stability criteriaMed - High - Tit
Description
Without electrode and without stirrer
Dimensions (L x W x H)162 x 185 x 56mm
High definition color TFT display, backlit
Frequency50 - 60Hz
Warranty 3 years
GLP Si
Degree of protection IP54 IP
Indication of calibration data Yes with report
Indication of buffers used for calibration Yes with icon
Indication of the state of the electrode Si with graph
Inputs BNC - RCA
Selectable languages Eng - Ita - Deu - Esp - Fra - Por
Memory / Datalogger1000
NamepH 8 Pro
Parameters pH - mV - ORP - T
Password Yes, 8 numeric characters
Weight0.709 kg
ORP calibration points 1 automatic value - 1 user value
pH1 calibration points ... 5 automatic values - 2 user values
Measurement range mV -2000 ... +2000 mV
ORP mV measuring range -2000 ... +2000 mV
pH measurement range -2,000 ... +16,000 pH
Measuring range Temperature -20.0 ... +120.0 °C
Calibration report Yes, printable
ORP resolution 0.1/1(auto)mV
Resolution pH 0.1 / 0.01 / 0.001 pH
Temperature resolution 0.1 °C
Acoustic signal Yes
Alarm thresholds pH Min - Max
pH USA - NIST - DIN 19266 recognized buffers
Working temperature 0 ... +45 °C
Calibration due timer with alarm Yes
Analog Display Yes